Check the manometer on the pipe. The liquid levels should sit apart, close to the line marked at start-up. Liquid sitting even on both sides means no suction. Then confirm with a retest every two years.
More detail
A U-tube manometer shows suction as a height difference between its two columns, so the habit is simple: glance at it when you are in the basement and compare it with the start-up mark. A big drift in either direction is worth a call; level liquid means the fan has stopped, the breaker has tripped, or the pipe is blocked, which in a Nebraska winter can mean ice at an exterior discharge. Some systems use an electronic monitor or alarm instead, which should reset on its own after a power outage. Listen for the fan, and check the labeled breaker. A healthy gauge proves air is moving, not that the room is under 4 pCi/L, which is why the two-year retest still matters. The repair service covers fans, gauges, and seals.